AutoSalt (AQAc™)
$1,200.00 – $16,500.00
Select a complete Autosalt System
or
Autosalt Base System + additional elements
See Technical Documents below for additional product detail
Description
Base Automated salt dilution system includes:
- AQAc custom control module
- Creek Pressure Transducer (PT)
- Reservoir PT
- Left Bank and Right Bank T-HRECS self-logging EC-T probes with Solar Panel, Li-ion battery, and LoRa for long-range radio comms
- Proprietary salt injection system
- 3 year Basic license to the “Salt Portal” salt dilution database management system and Rating Curve (RC) development tools
- 3 year warranty
Automated salt injection system that does the work for you.
It can be difficult to obtain a full range of flow measurements for your hydrometric rating curve. Resources are often wasted visiting sites at similar flow conditions. At Fathom Scientific, we’ve been developing the Automated Q Acquisition (AQAc…a.k.a. AutoSalt™), since 2008 to address these and other challenges. The AutoSalt (300L Tang and Stand) System consists of a control system, 300 litre brine tank and stand, Creek Pressure Transducer, 2x T-HRECS self-logging EC-T probes, and a proprietary salt injection system. Systems have been installed at >20 locations around the province of BC since 2008 and collected hundreds of automated discharge measurements.
How Does it Work?
The system works by first sensing the water level in the Creek. This is essentially a redundant water level sensor to support a Grade A Hydrometric record. The AQAc then decides to inject brine based on a combination of logical rules, preferably injecting brine on the falling limb of a hydrograph. Alternatively, a Regular Injection Interval can be set. Measurements can also be triggered via Telemetry. EC-T data is relayed back to the Control module via LoRa radios, as well as logged continuously at the D/S Temperature – High Resolution Electrical Conductivity Serial (T-HRECS) device EC-T sites. Injected brine volume is measured by three independent methods. Due to the high resolution and sensitivity of the T-HRECS EC-T sensors (and the paired U/S T-HRECS) we can use very low salt doses and still achieve low SDIQ uncertainty. Typically we set the brine [NaCl] to 20%, and aim for 1 litre of brine per m³/s. Tanks come in 200 and 300 litre sizes. This implies we can measure between 200-300 cumulative m³/s per visit, i.e. 10 measurements of 20 m³/s (for the 200 l tank) or 200 measurements of 1m³/s. Of course, in reality it will be a range of flows.
Systems have been installed at numerous locations around the world including New Zealand, Germany,
UK, and Canada for agencies such as NIWA, TUM, Helmholtz Institute, and WSC, along with several hydropower and mining operations.
TECHNICAL DOCUMENTS
Complete Systems:
AQAc System (200L-Backpack)
AQAc System (300L-Aluminum Stand)
Custom Build:
AQAc: Base Product
AQAc: 300L Tank and Stand
AQAc: 200L Tank
AQAc: Power System
AQAc: Telemetry LTE
AQAc: AQAc Data Wrangler
Add-ons:
AQAc: PicoMag Upgrade on AutoSalt
AQAc: Threcs (additional)
AQAc: Armoured Thalweg Instrument Enclosure(ArTIE™) System
AQAc: Warranty extension to 5 years
Brochure and Technical Data Sheet
Quantifying and Controlling Error in Salt Dilution Flow Measurements
Autosalt Systems come with a subscription to the Salt Portal
CF.T Explanation:
A requirement of any automated system is to either know the Calibration Factor – Temperature compensated (CF.T) or measure the CF.T in situ. We have partnered with academic institutions and other consultants to determine the variance of the CF.T in streams and rivers in B.C. We’ve found this value to be relatively constant (+/-1.6% at 95% confidence) with calibrated instrumentation and careful calibration procedures. Browse our recent presentations on the Derivation, Uncertainty, and Variance of the Calibration Factor used in Salt Dilution Flow Measurements (or read the associated post) and Quantifying and Controlling Error in Salt Dilution Flow Measurements (and the associated post).
INSTALLATION WARRANTY
For $13,500 CAD, the AutoSalt system is good value. We will install the system for $2000 CAD at most sites + transportation + disbursements. We strongly recommend our assistance for the first installation. AutoSalt has a 3 year limited warranty on parts and includes a subscription to WIT-HM to semi-automatically process SD Measurements, manage measurements, and develop a Maximum-Likelihood Hydraulically-Based Rating Curve.
We also offer a rental option of $1500/month. For rentals, the same installation costs apply: $2000 CAD at most sites + transportation + disbursements.
Ask about our Adventure Discount.
For more information, please contact us.
TESTIMONIAL
I can’t physically be…everywhere, all the time. As much as I like to think of myself as a professional storm chaser, I often miss those golden opportunities to capture flow measurements along important segments of my stage-discharge relationship because rain events happen too quickly, or worse, they happen overnight…With the AutoSalt installed at a station I can capture discharge measurements without being on site.
Lyssa Maurer, Expert Hydrometric Technologist for National Hydrological Services – Environment and Climate Change Canada
Description
Base Automated salt dilution system includes:
- AQAc custom control module
- Creek Pressure Transducer (PT)
- Reservoir PT
- Left Bank and Right Bank T-HRECS self-logging EC-T probes with Solar Panel, Li-ion battery, and LoRa for long-range radio comms
- Proprietary salt injection system
- 3 year Basic license to the “Salt Portal” salt dilution database management system and Rating Curve (RC) development tools
- 3 year warranty
Automated salt injection system that does the work for you.
It can be difficult to obtain a full range of flow measurements for your hydrometric rating curve. Resources are often wasted visiting sites at similar flow conditions. At Fathom Scientific, we’ve been developing the Automated Q Acquisition (AQAc…a.k.a. AutoSalt™), since 2008 to address these and other challenges. The AutoSalt (300L Tang and Stand) System consists of a control system, 300 litre brine tank and stand, Creek Pressure Transducer, 2x T-HRECS self-logging EC-T probes, and a proprietary salt injection system. Systems have been installed at >20 locations around the province of BC since 2008 and collected hundreds of automated discharge measurements.
How Does it Work?
The system works by first sensing the water level in the Creek. This is essentially a redundant water level sensor to support a Grade A Hydrometric record. The AQAc then decides to inject brine based on a combination of logical rules, preferably injecting brine on the falling limb of a hydrograph. Alternatively, a Regular Injection Interval can be set. Measurements can also be triggered via Telemetry. EC-T data is relayed back to the Control module via LoRa radios, as well as logged continuously at the D/S Temperature – High Resolution Electrical Conductivity Serial (T-HRECS) device EC-T sites. Injected brine volume is measured by three independent methods. Due to the high resolution and sensitivity of the T-HRECS EC-T sensors (and the paired U/S T-HRECS) we can use very low salt doses and still achieve low SDIQ uncertainty. Typically we set the brine [NaCl] to 20%, and aim for 1 litre of brine per m³/s. Tanks come in 200 and 300 litre sizes. This implies we can measure between 200-300 cumulative m³/s per visit, i.e. 10 measurements of 20 m³/s (for the 200 l tank) or 200 measurements of 1m³/s. Of course, in reality it will be a range of flows.
Systems have been installed at numerous locations around the world including New Zealand, Germany,
UK, and Canada for agencies such as NIWA, TUM, Helmholtz Institute, and WSC, along with several hydropower and mining operations.
Additional information
Weight | 50 kg |
---|---|
Dimensions | 1500 × 1500 × 1500 cm |
Options | AutoSalt System (200L-Backpack), AutoSalt System (300L-Aluminum Stand), AutoSalt – Base System, 300L Tank and Stand, 200L Tank, Power System, AQAc Telemetry LTE + subscription, AQAc Data Wrangler, T-HRECS (additional – Helios), Armoured Thalweg Instrument Enclosure(ArTIE™) System, PicoMag Upgrade on AutoSalt V1, 5 year Upgrade, Maintenance, and Service |
TECHNICAL DOCUMENTS
Complete Systems:
AQAc System (200L-Backpack)
AQAc System (300L-Aluminum Stand)
Custom Build:
AQAc: Base Product
AQAc: 300L Tank and Stand
AQAc: 200L Tank
AQAc: Power System
AQAc: Telemetry LTE
AQAc: AQAc Data Wrangler
Add-ons:
AQAc: PicoMag Upgrade on AutoSalt
AQAc: Threcs (additional)
AQAc: Armoured Thalweg Instrument Enclosure(ArTIE™) System
AQAc: Warranty extension to 5 years
Brochure and Technical Data Sheet
Quantifying and Controlling Error in Salt Dilution Flow Measurements
Autosalt Systems come with a subscription to the Salt Portal
CF.T Explanation:
A requirement of any automated system is to either know the Calibration Factor – Temperature compensated (CF.T) or measure the CF.T in situ. We have partnered with academic institutions and other consultants to determine the variance of the CF.T in streams and rivers in B.C. We’ve found this value to be relatively constant (+/-1.6% at 95% confidence) with calibrated instrumentation and careful calibration procedures. Browse our recent presentations on the Derivation, Uncertainty, and Variance of the Calibration Factor used in Salt Dilution Flow Measurements (or read the associated post) and Quantifying and Controlling Error in Salt Dilution Flow Measurements (and the associated post).
INSTALLATION WARRANTY
For $13,500 CAD, the AutoSalt system is good value. We will install the system for $2000 CAD at most sites + transportation + disbursements. We strongly recommend our assistance for the first installation. AutoSalt has a 3 year limited warranty on parts and includes a subscription to WIT-HM to semi-automatically process SD Measurements, manage measurements, and develop a Maximum-Likelihood Hydraulically-Based Rating Curve.
We also offer a rental option of $1500/month. For rentals, the same installation costs apply: $2000 CAD at most sites + transportation + disbursements.
Ask about our Adventure Discount.
For more information, please contact us.
TESTIMONIAL
I can’t physically be…everywhere, all the time. As much as I like to think of myself as a professional storm chaser, I often miss those golden opportunities to capture flow measurements along important segments of my stage-discharge relationship because rain events happen too quickly, or worse, they happen overnight…With the AutoSalt installed at a station I can capture discharge measurements without being on site.
Lyssa Maurer, Expert Hydrometric Technologist for National Hydrological Services – Environment and Climate Change Canada